General
The SIP Trunk from Teleforte was first tested and released with SwyxWare 11.38.0.0.
The SIP Trunk from Teleforte is a SIP Trunk with user authentication, i.e. you receive information on user ID, user name and password. The names may differ, or you may only receive a name or ID with password. In this case the user ID is identical to the user name when configuring the SIP trunk in SwyxWare.
Platforms
SwyxWare
The SIP Trunk from Teleforte can be used from SwyxWare 11.38.0.0 on.
SwyxON
The SIP Trunk from Teleforte is suitable for central connection in the data center.
Configuration
When creating the SIP trunk group, select the profile 'Teleforte (DE)'.
IMPORTANT! With the older profile, "Automatic" is configured as the transport protocol for the SIP Trunk. This can lead to a secured connection (TLS) to the provider being established and no voice transmission taking place during calls. It is therefore necessary to configure the Transport Protocol to "TCP" in the properties of the SIP trunk group in the tab "Encryption". The actulal profile already has TCP preconfigured as transport protocol. |
Codec configuration
For FAX transmission it is necessary to select the option "Remove T.38 from first negotiation (SIP INVITE)" via the tab "Codecs/Channels" of the properties of the created SIP trunk.
Tested features
- Incoming/outgoing national /international calls
- Correct Calling Line Identification (CLI) on national / intenational calls
- CLIP No Screening national
- Holding and retrieving calls
- Toggeling between two calls
- Call transfer
- Call forwarding
- Conferencing
- Mutually supported codecs: G.722/ G.711a/ G.711u
- Incoming/outgoing DTMF signaling in accordance with via RFC2833
- FAX transmission via T.38/G.711
Restrictions
None
Tests
09/04/2019 with SwyxWare 11.38.0.0
Disclaimer
Verifying interoperability between different SIP providers and the Swyx solution is part of the Enreach Technology Alliance Programme (TAP) tasks. Due to different implementations of the SIP RFCs, it is necessary to determine and provide an individual configuration for each SIP provider.
Within the TAP, Enreach tests a large number of national and international SIP providers in order to make statements about the interoperability with the Swyx solution and the functional scope of the respective SIP trunk. These results and, if needed, configuration advice are published in Help Center articles.
Enreach is in close contact with selected SIP providers to ensure a quick troubleshooting in case of incompatibilities. In addition, tests are repeated at regular intervals to ensure consistent quality.
Despite regular retests it cannot be excluded that incompatibilities with the Swyx solution may occur due to changes in the SIP connection on the provider side or that the provided profile is no longer valid. After creating the trunk group or SIP trunk, the profile settings should be compared with the provider's information and adjusted accordingly in case of deviations.
However, should incompatibilities or problems occur with a tested SIP trunk, no claims for recourse against Enreach GmbH can be derived from this. In such cases, you can contact Enreach Support via your specialist dealer.
The third-party contact information included in this article is provided to help you find the technical support you need. This contact information is subject to change without notice. Swyx in no way guarantees the accuracy of this third-party contact information nor is responsible for it's content.
Comments
0 comments
Please sign in to leave a comment.